Quantum

  • Product Type: Deionized Water Heaters

     

     
    Trebor's thin film on quartz electric resistive heating technology is ideal for your ultra high purity DI water heating applications when process control, cleanliness, and system uptime are of the utmost importance. This patent pending technology utilizes GE 214 semiconductor grade quartz tubes bonded with a resistive metallic film. Trebor's patented sealing technology provides an ultra pure flow path with no elastomer o-ring seals or particle traps. This unique design creates a compact, ultra clean heating module with an MTBF greater than 20,000 hours.
     

     
    Product Features
     
    ♦ LEADING EDGE TECHNOLOGY - Patented thin-film on quartsz electrical resistance heater element provides exceptional temperature response and improved reliability over IR heating which requires frequent bulb change outs. The propriety design has no metal exposure and virtually eliminates contamination risk in the event of element failure, unlike most immersion style heaters. No external air or nitrogen purge is required.

    ♦ VERSATILE CONTROL OPTIONS - Standard Modbus/TCP offers the industry's first DI water heater Ethernet control capability. Many other remote system monitoring and control options available to meet virtually communication requirements and protocols.

    ♦ COMPACT & CONVENIENT - The modular element allows for very compact system design and can be changed out in less than 15 minutes when required. LCD color touch screen display provides easy user input and diagnostic feedback.

    ♦ HIGH PERFORMANCE - Efficient heat transfer and low resident fluid volume produces fast response to changes in flow or temperature set point using multi-loop PID control with zero crossfire SSRs.

    ♦ ULTRA CLEAN DESIGN - High purity flow path of GE 214 semiconductor grade quartz, PTFE, and PFA, with no elastomer o-rings and no NPT threads or dead-legs to create particle traps.

    ♦ SAFETY COMPLIANT - TUV third party compliance testing and inspection to CE, SEMI S2 & S8, and NFPA79 standards.
     
    ♦ USER EVENT CONTROL - Virtually eliminate fluid temperature fluctuations caused by process flow changes. Signal the heater of a flow change and within one second, the heater will automatically adjust to minimize the effect on process temperature.
     

     
     

     
    SPECIFICATIONS
     
     
     
     
    DIMENSTIONS & INSTALLATION
     
     

     
    Heater Selection Chart
     
    Power
    Voltage (50/60 Hz)
    Current Rating (Amps)
    Heating Modules
    30 kW
     
    380
    415
     
    45
    3
    30 kW
     
     
     
    480
    40
    3
    36 kW
    208
     
     
     
    110
    3
    36 kW
     
     
     
    480
    45
    3
    48 kW
    208
     
     
     
    145
    4
    60 kW
    208
     
     
     
    185
    5
    60 kW
     
    380
    415
     
    95
    6
    60 kW
     
     
     
    480
    75
    6
    72 kW
    208
     
     
     
    220
    6
    72 kW
     
     
     
    480
    90
    6
     
     
     
     
     
     
     
    84 kW
    208
     
     
     
    260
    7
    90 kW
     
    380
    415
     
    140
    9
    90 kW
     
     
     
    480
    110
    9
    96 kW
    208
     
     
     
    295
    8
    108 kW
    208
     
     
     
    330
    9
    108 kW
     
     
     
    480
    135
    9
    120 kW
    208
     
     
     
    370
    10
    120 kW
     
    380
    415
     
    185
    12
    120 kW
     
     
     
    480
    150
    12
    132 kW
    208
     
     
     
    405
    11
    144 kW
    208
     
     
     
    440
    12
    144 kW
     
     
     
    480
    180
    12
    180 kW
     
    380
    415
    480
     
    15
    216 kW
     
     
     
    480
     
    18
    Refer to back page for determining the right heater size for your application.
     
     
    System Dimesions (in/cm)
    System Weight
    Power
    A
    B
    C
    Lbs/kg
    30 kW
     
    200/91
    To
    250/114
    36 kW
    69.0 in
    24.0 in
    20.0 in
    48 kW
    175.3 cm
    61.0 cm
    50.8 cm
    60 kW
     
    72 kW
     
     
     
     
     
    84 kW
     
    410/186
    To
    530/240
    90 kW
    96 kW
    69.0 in
    38.0 in
    20.0 in
    108 kW
    175.3 cm
    96.5 cm
    50.8 cm
    120 kW
     
    132 kW
    144 kW
     
     
    180 kW
    Consult Factory
    216 kW
     

     
    How to order
     
    Use the code numbers for ordering the proper configuration for your Quantum Heater.
    HEATER
    QTM
    Quantum Deionized DI Water Heater
    POWER
    030
    036
    048
    060
    072
    084
    090
    096
    108
    120
    132
    144
    180
    216
    30 kW
    36 kW
    48 kW
    60 kW
    72 kW
    84 kW
    90 kW
    96 kW
    108 kW
    120 kW
    132 kW
    144 kW
    180 kW
    216 kW
    VOLTAGE
    V208
    V380
    V415
    V480
    208VAC 50/60 Hz, 3 phase
    380VAC 50/60 Hz, 3 phase
    415VAC 50/60 Hz, 3 phase
    480VAC 50/60 Hz, 3 phase
    PLUMBING
    A
    B
    Titanium J-type, fast acting
    PFA coated J-type
    OPTIONS
    Options are available at an additional cost:
    Contact factory for part number when requesting options.
     
    Casters (Replace feet)
    Modbus / RTU
    Device Net
    Analog Interface / Remote EMO
    Dual Outlet Plumbing
    Example of an order number based on configuration options:
    QTM
    060
    V480
    A
     

     
    Sizing Formula
     
    Required kW = 0.264(Flow)(Temp Delta)
     
    Conversion Calculations:
    GPM = LPM x 3.8
    °C = 5/9(°F - 32)
     
    Heater Sizing Formula Example
     
    Ambient Water Temp = 25°C
    Desired Process Temp = 70°C
    Temperature Delta = 45°C
     
    Required kW = 0.264(4 GPM)(45°C) = 47.5kW
     
    For optimal temperature response and to compensate for seasonal changes in ambient water temperature, we recommend adding 20% excess heating capacity.
     
    47.5 kW(1.2) = 57kW >>> Trebor recommends a 60kW heater for this application 

Deionized Water Heaters

 

toptop